9 min read

How to Track ISP Circuit IDs, Demarcs, and Terminations Across Providers

A working procedure for circuit records: the fields to capture, API calls to write them, the commands that verify a handoff, and the queries that find incomplete circuits before the next outage.

ByAndré Ribeiro· Founder, Obelinf
How to Track ISP Circuit IDs, Demarcs, and Terminations Across Providers
How to Track ISP Circuit IDs, Demarcs, and Terminations Across Providers · October 18, 2026
On this page

A circuit outage starts with a specific kind of delay. The link is down, the team knows the internal name, and the carrier needs a reference nobody can find quickly. The carrier reference exists on the invoice, the demarc exists on the floor plan, and the port exists on a router, and the outage would be ten minutes shorter if all three were recorded together. That is the entire case for treating a circuit as structured data rather than a line in a spreadsheet.

This is the working version of that idea. It covers the exact fields to capture, the API calls that write them at each stage of an order, the commands that confirm a handoff is healthy before you call it done, and the queries that surface the circuits still missing a reference or a termination. The order of operations matters as much as the fields, because the details are cheapest to record while the install is still fresh.

At a Glance: Where Circuit Identity Lives

Obelinf Spreadsheet Carrier portal only
Provider circuit ID Searchable field on the circuit Free text column, inconsistent One portal per carrier
Order and service reference Kept in the circuit description Another column, rarely updated Order history if findable
Demarc and cross connects Linked to the interfaces they reach Notes cells that go stale Usually absent
Endpoint equipment A and Z ends point at real interfaces Two device name columns Absent
Cross carrier view One query across every provider One file, if maintained One login per provider
Change history Immutable and per field Manual or none Carrier side only

The fields to capture, and where each one comes from

Every value on a circuit record traces back to a person, a contract, or a device, and knowing the source makes the record fill itself in a predictable order. Keep this list as the definition of done for a new circuit.

Field API name Example Source
Internal name name NYC to DC1 primary Your team
URL slug slug nyc-dc1-primary Your team
Provider provider_id Zayo Contract
Circuit type type_id DIA Contract
Carrier reference cid carrier string, verbatim Carrier portal or invoice
Provisioned rate bandwidth 1000 (Mbps) Contract
A and Z sites site_a_id, site_b_id NYC, DC1 Design
Terminations interface_a_id, interface_b_id Gi0/0/0 on rtr-nyc-01 Handoff
Status status planned, active, decommissioned Lifecycle
Order details description order number, contract ID Procurement

The first four are known before the carrier issues anything, which is why the record should exist from the day the order is placed. The last three are only known once the service is live, and those are the ones that get skipped when nobody owns the step.

Five identifiers that describe one circuit, from the order number to the internal record Order number from the contract Circuit ID from the carrier Demarc NID or ONT Handoff port cross connect Circuit record one searchable item Four of the five identifiers are created by someone else. Record them while the install paperwork is still in front of you, because that is the last moment they are all known.

Look up the IDs before you write the record

The API takes IDs rather than names, so the first step is resolving the provider, type, site, and interface you intend to reference. Save the results in environment variables for the session and keep the commands in a small script so the next circuit takes seconds.

export OBELINF_API_KEY="your_read_write_key"
export OBELINF_ORG="acme-netops"

# Provider and type IDs
curl --fail --silent --show-error -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  "https://api.obelinf.com/${OBELINF_ORG}/circuit-providers?q=zayo" \
  | jq -r '.circuit_providers[] | [.id, .name] | @tsv'

curl --fail --silent --show-error -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  "https://api.obelinf.com/${OBELINF_ORG}/circuit-types?q=dia" \
  | jq -r '.circuit_types[] | [.id, .name] | @tsv'

# Sites at each end
curl --fail --silent --show-error -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  "https://api.obelinf.com/${OBELINF_ORG}/sites?q=nyc" \
  | jq -r '.sites[] | [.id, .name] | @tsv'

The terminations are resolved the same way, and the interface list filters by device so you can find the exact port that the handoff reaches.

curl --fail --silent --show-error -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  "https://api.obelinf.com/${OBELINF_ORG}/device-interfaces?device_id=${ROUTER_ID}&limit=200" \
  | jq -r '.interfaces[] | [.id, .device_name, .name, (.description // "")] | @tsv'

Copy the interface ID for the port the circuit lands on, not the port you wish it landed on. If the handoff is still a patch panel and no device interface exists yet, leave the termination empty and come back to it, because a placeholder ID is worse than an honest gap.

Record the circuit when the order is placed

Create the record with everything known on day one, status set to planned, and no carrier reference yet. This is the step that most teams skip, and it is the reason circuit IDs end up in email.

cat > circuit.json <<JSON
{
  "name": "NYC to DC1 primary",
  "slug": "nyc-dc1-primary",
  "provider_id": "${PROVIDER_ID}",
  "type_id": "${TYPE_ID}",
  "site_a_id": "${SITE_A_ID}",
  "site_b_id": "${SITE_B_ID}",
  "status": "planned",
  "bandwidth": 1000,
  "description": "Order 88412, 2 year term, A end rtr-nyc-01"
}
JSON

curl --fail --silent --show-error -X POST \
  -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  -H "Content-Type: application/json" \
  --data @circuit.json \
  "https://api.obelinf.com/${OBELINF_ORG}/circuits" \
  | jq '.circuit | {id, name, cid, bandwidth, status}'

Save the returned id as CIRCUIT_ID. From here the record grows by patch as each milestone passes, rather than being created once at the end from memory.

Add the carrier reference the day it is issued

When the carrier confirms the order it issues the circuit ID, the reference that every support call will start with. Store it exactly as written, including punctuation and letter case, because support engineers read it back character by character into a system that will reject a close match.

curl --fail --silent --show-error -X PATCH \
  -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  -H "Content-Type: application/json" \
  -d "{\"cid\":\"${CARRIER_CID}\",\"status\":\"active\"}" \
  "https://api.obelinf.com/${OBELINF_ORG}/circuits/${CIRCUIT_ID}" \
  | jq '.circuit | {name, cid, status, bandwidth}'

If the carrier gives you more than one reference, keep the primary circuit ID in cid and put the order number, the service ID, and the account number in description as labeled text. Two identifiers in one field is the fastest way to lose both.

Attach the terminations when the handoff is made

The terminations are the part of the record that pays off during an incident, because they turn a question about a carrier reference into a query about a cable you can go find. Patch them in as soon as the ports are assigned.

curl --fail --silent --show-error -X PATCH \
  -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  -H "Content-Type: application/json" \
  -d "{\"interface_a_id\":\"${IF_A_ID}\",\"interface_b_id\":\"${IF_B_ID}\"}" \
  "https://api.obelinf.com/${OBELINF_ORG}/circuits/${CIRCUIT_ID}" \
  | jq '.circuit | {name, interface_a_device_name, interface_a_name, interface_b_device_name, interface_b_name}'

The response returns the resolved device and interface names, which is worth reading back to confirm you attached the right end to the right site. A circuit whose A end resolves to a device in the wrong site is a copy and paste error that is trivial to catch here and expensive to catch during a failover.

Where carrier responsibility ends and yours begins, from the provider core to your router interface Carrier responsibility Provider core central office Demarc (NID or ONT) test and handoff Meet me room and building entrance cross connect Demarc Your responsibility Handoff port patch panel or panel Router interface the record points here Patching, optics, and the interface you monitor Record the demarc as a location and a device, not as a synonym for the handoff. It is the difference between dispatching a field engineer and opening a carrier ticket.

Verify the handoff before you call it done

The record is not complete until the port is known to be healthy, because a circuit documented as active on a flapping interface is worse than one documented as planned. Read the link state, the error counters, and the optical levels on the terminating device.

show interfaces Gi0/0/0
show interfaces Gi0/0/0 | include error|CRC|drops
show interfaces Gi0/0/0 transceiver
show lldp neighbors GigabitEthernet0/0/0 detail

On Juniper the same checks come from the interface and the optics diagnostics, and on a Linux host from the link statistics and the module DOM data.

show interfaces ge-0/0/0 extensive | match "Input errors|CRC|Link mode"
show interfaces diagnostics optics ge-0/0/0 | match "Laser output|Receiver signal"
ethtool eth0 | grep -E "Speed|Duplex|Link detected"
ethtool -S eth0 | grep -iE "crc|error|drop"
ethtool -m eth0

Three readings decide whether you close the ticket. The link should be up at the speed the contract expects and the interface should be full duplex where the optic supports it. Error counters should be flat across a second reading a few minutes later. The receive optical level should sit inside the range the transceiver publishes, not at either extreme, because a level near the edge is a failure waiting for a temperature change. Write the known good numbers into the circuit description or a note, so the next engineer has a baseline instead of a guess.

Find incomplete records before the next outage

A circuit inventory drifts quietly, and the fix is a short set of queries you run on a schedule. Pull the whole list once and keep the JSON, then filter it locally.

curl --fail --silent --show-error -H "Authorization: Bearer ${OBELINF_API_KEY}" \
  "https://api.obelinf.com/${OBELINF_ORG}/circuits?limit=500" > circuits.json

# Active circuits with no carrier reference
jq -r '.circuits[] | select(.status == "active" and .cid == null)
  | [.name, .provider_name, .site_a_name, .site_b_name] | @tsv' circuits.json

# Circuits missing a termination at either end
jq -r '.circuits[] | select(.interface_a_id == null or .interface_b_id == null)
  | [.name, .status, (.interface_a_name // "A missing"), (.interface_b_name // "Z missing")] | @tsv' circuits.json

# Circuits with no provisioned rate recorded
jq -r '.circuits[] | select(.bandwidth == null) | [.name, .provider_name, .type_name] | @tsv' circuits.json

# A provider with no circuit type suggests a rushed record
jq -r '.circuits[] | select(.provider_id != null and .type_id == null)
  | [.name, .provider_name, .cid] | @tsv' circuits.json

Run these quarterly and after any migration. An active circuit with no carrier reference is the highest priority, because that is the record that will slow down a support call. A missing termination means nobody can say which port to check. A blank rate means nobody can answer a capacity question without opening the contract.

What to have open before you call support

Most of the elapsed time in a circuit incident is spent assembling facts that should already be on one screen. Before you dial, have these four things visible, and read the circuit ID off the record rather than from memory.

Four facts to have on screen before opening a carrier support ticket Carrier circuit ID read verbatim from the record, not from memory never paraphrase it Demarc location meet me room, suite, or building entrance who owns what past it Handoff port device and interface the circuit terminates on from the circuit record Last known good optical level, error counts, and the last change made before the failure A carrier will ask for the reference first and the handoff second. A record that answers both turns the call into a status check instead of an interview.

The habit that keeps all of this honest is unglamorous. Write the carrier reference down exactly as issued at the moment it is issued, point both ends at the ports they touch as soon as those ports are assigned, and run four queries a quarter to find what drifted. Circuits that live in one structured list, with the carrier reference beside the interfaces they feed and edges rendered between multi site networks in the network topology, are the ones that turn the next outage into a ticket instead of a translation exercise.

Frequently Asked Questions

What is an ISP circuit ID?
An ISP circuit ID is the carrier's own reference for your service, a short alphanumeric string that appears on your invoice, inside the carrier portal, and on every support ticket you open. It is not your hostname and not your internal circuit name, but the support desk will usually ask for it before it looks at anything else, so store it verbatim next to your own record rather than in an email thread.
What is a demarcation point on a WAN circuit?
The demarcation point, usually shortened to demarc, is the boundary where the carrier's responsibility ends and yours begins. On a fiber circuit it is often an optical network terminal or network interface device in a meet me room or building entrance rather than in your own rack. The provider maintains the service to that point, and everything past it, including the cross connect, patch cable, and router interface, is yours.
How do I find the device interface a circuit terminates on?
Query the interface list filtered to the device you expect, then match on the port name or description. In Obelinf you can list interfaces for a device with `GET //device-interfaces?device_id=` and read the returned `name` and `description` fields, then store the interface ID as the circuit's A or Z termination.
Should I store the carrier circuit ID exactly as the carrier writes it?
Yes, keep the value verbatim, including punctuation and letter case, because support engineers read it back character by character and a rewritten version will not match their system. Keep your own name and slug in separate fields so the record stays searchable in your naming convention without altering the carrier reference.
How do I check whether a circuit handoff is healthy?
Look at the interface on the device that terminates the circuit and read three things: whether the link is up at the expected speed, whether error counters such as CRC and input errors are flat, and whether the optical receive level sits inside the transceiver's published range. Confirm the far end with an LLDP or CDP neighbour lookup, then record the result with the circuit so the next engineer has a known good baseline.
How do I keep WAN circuit records current across several providers?
Keep one list that spans every provider with the same fields filled in the same way, and review it after every order, upgrade, and decommission rather than only when something breaks. The teams that stay current treat the circuit record as part of the install checklist. Obelinf holds the carrier reference, the provisioned rate, and the terminations in the same inventory as the devices, so a circuit ID is searchable next to the port it feeds.

Free Tools

Put this into practice with the free calculators, reference tables, and checklists in the Obelinf toolkit.

Stop reaching for a spreadsheet

Obelinf keeps every subnet, device, circuit, and rack in one live source of truth, with audit logs and a topology view. Free for personal use.